This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.
ITEMLIST
Products Infomation
Bench-type optical power meter suitable for R&D and production of optical disks
The 8250A is a bench-type optical power meter, which is most suitable for R&D and production of LDs, optical pickups, and drives for optical disks. It has 0.001 dB resolution and 5½-digit display and is also quipped with GPIB and USB interfaces as standard, allowing easy automated system establishment. Nine kinds of optical sensors with various purpose (general-purpose, blue-violet, high-power, three-wavelength) and different shapes (thin-type, cylindrical-type) are available. The three-wavelength optical sensors 82314B, 82324B and 82314BW are capable of measuring 405 nm, 650 nm, 780 nm wavelength ranges. The blue-violet optical sensors 82312B and 82322B have realized a flat wavelength sensitivity characteristic and low dependency on an angle of incidence in the 405 nm range. The high-power optical sensors 82313B and 82323B enable high-power measurement of up to 200 mW. Furthermore, the optical sensors for the TQ8210/TQ8215 series are also usable.
Optical Power Meter
Model:
8250A
Maker:
ADC CORPORATION
Feature
- 5 ½-digit display
- A desk-top type; equipped with GPIB and USB
- Wide lineup of sensors are available for each application
Specifications
■ Applicability table for the nine product types of sensors ■
Shape | Part Number | Wavelength Range | Calibration Wavelength | Power Range | Light Receiving Area | |
General-purpose | Thin | 82311B | 390 to 1100 nm | 780 nm | 1 nW to 50 mW | Approx. 9.5 mm × 9.5 mm |
Cylinder | 82321B | 390 to 1100 nm | 780 nm | 1 nW to 50 mW | Approx. 8.5 mmφ | |
High-power | Thin | 82313B | 390 to 1100 nm | 650 nm | 10 nW to 200 mW | Approx. 8.5 mmφ |
Cylinder | 82323B | 390 to 1100 nm | 650 nm | 10 nW to 200 mW | Approx. 8.5 mmφ | |
Blue-violet | Thin | 82312B | 390 to 450 nm | 405 nm | 10 nW to 100 mW | Approx. 10 mm×10 mm |
Cylinder | 82322B | 390 to 450 nm | 405 nm | 10 nW to 100 mW | Approx. 8.5 mmφ | |
Three-wavelength | Thin | 82314B | 390 to 900 nm | 405 nm | 10 nW to 100 mW | Approx. 10 mm×10 mm |
Thin and large | 82314BW | 390 to 900 nm | 405 nm | 10 nW to 100 mW | Approx. 18 mm×18 mm | |
Cylinder | 82324B | 390 to 900 nm | 405 nm | 10 nW to 100 mW | Approx. 8.5 mmφ |
*In addition to the calibrated wavelength indicated, calibration with additional wavelengths (405, 650, 780 nm) is possible as an option.
*The wavelength sensitivity of the 82311 and the 82321 is corrected by using the typical values. As for the 82311, correction by measurement is possible as an option.