CONTENTS CONTENTS

ITEMLIST

Products Infomation

ADCMT IR Meter 4000 / 4005X Series

Modular-system IR meter with maximum 4 channels

The IR meter consists of the compact mainframe 4000 having two slots and the modular units 40051, 40052, 40053 and 40054. It configures up to 4 channels by combining the modular units.

In recent years, it is necessary to improve the takt time of manufacturing and inspection in production lines of parts or components. Consequently, measuring instruments used in these production lines require higher measuring speed, multiple channles. space saving and other optimal functions.

This IR meter can satisfy such needs by adopting the modular system.

IR Meter

Model:

4000 / 4005X Series

Maker:

ADC CORPORATION

Download Materials

Features

2U half-size compact mainframe with 2 slots

  • Maximum number of modules: 2
  • Interface: USB, GPIB, LAN, RS232
  • Handler interface: 4 channels
  • Digital I/O: 8 bits

Micro-current/ultra-high resistance meter modules for 4000

  • Current measurement range: 10 fA to 3.2 mA
  • High-speed current measurement at 1.5 ms by integration method
  • Voltage source: ±200 V (40051/40052)
    +300 V, -100 V (40053/40054)
    +2000 V, -200 V (40057)
  • Contact check: 0 to 100 pF with resolution of 0.1 pF
  • Handler interface: INDEX, EOM, HI, GO, LO, NC

Specifications

Model 4000+40051/40052 4000+40053/40054

4000+40057

Number of channels 1 to 4 1 to 2
Number of digits, maximum display 5½ digits、319999
Floating voltage 200 V 300 V 0 V
Measurement Current Range 300 pA~3 mA   
Minimum resolution 1 fA
Measurement accuracy 0.3 %   
Input bias current 100 fA or under/td>
Input resistance 50 Ω/1 kΩ

Resistance

(Calculation)

Measurement range 312 Ω to 316 Ω  312 Ω to 317 Ω
Range (300 pA to 3 mA)
Measurement accuracy  0.35 %
Source Voltage Range -200 V to +200 V -100 V to +300 V -200 V to +2000 V
Minimum resolution 1 mV   
Source accuracy 0.03 % 0.03 %(200 V)
0.2 % (2000 V) V
Voltage source range

±30 V/±3.2 mA

±30 V/±3.2 mA

+300 V, -100 V/±3.2 mA

±30 V/±3.2 mA

±200 V/±3.2 mA

+50 to +2000 V/0.8 mA

Voltage limit

10 μA to 3.2 mA
Resolution: 1 μA

10 μA to 3.2 mA
Resolution: 1 μA
0.8 mA/2000 V

Sweep Fixed, linear
Measurement function Integration time

1 ms/2 ms/5 ms/0.5 PLC/1 PLC/100 ms/200 ms

Measurement speed (IT2 ms)
TRG-INDEX (without CHK)
TRG-INDEX (with CHK)

 
2.6
4.1

Data memory

10000 data/channel

Sequence Depending on fixed sweep
Contact check

To be executed at every measurement
0.1 pF to 100 pF, 500 kHz/315 kHz, execution time: 1.5 ms

Calculation  RM, COMP  
Other functions

4-channel synchronization or 
asynchronization
Jig capacity open correction

2-channel synchronization or
asynchronization
Jig capacity open correction

INT CAL Available
Interface GPIB, USB, RS232, LAN

Get Adobe' Reader'

To view the pdf files, the Adobe Reader from Adobe Systems is required.

Researched by Shared Research Inc.
about Nihon Denkei Co., Ltd.