This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.


ITEMLIST
Products Infomation

EN/IEC 61000-4-2 Ed2 & ISO 10605 Ed2 Compliant
“NoiseKen” ESD simulators can reproduce and simulate the ESD from a charged human body intentionally for testing whether electronic equipments become malfunctioned or work correctly with the ESD influence, and the simulators conform to IEC61000-4-2 Standard which is standardized by International Electrotechnical Committee (IEC).
Electrostatic Discharge Simulator
Model:
ESS-S3011A & GT-30RA / GT-30R3302KA
Maker:
NOISE LABORATORY CO.,LTD.
Features
- EN/IEC 61000-4-2 Ed2 Compliant
- ISO 10605 Ed2 Compliant (Note: Optional gun head and CR units are required.)
- Pre-test
“3 pre-checking functions” taking the confirmable test into the account
“CR constant indicator” to ensure correct attachment is in place - During test
“Ten-key & Rotary knob” to ease the setting
“Infra-red Remote Controller” to allow remote Generator setting
“Discharge Detecting Function” to realize the air-discharge confirmation
“Lightest Discharge Gun in the market” for better continuous operation
“White LED light” to show Discharging points - After test
“Control Software” for Test Result Reporting and PC Control
free-downloadable from NoiseKen web-site
ESS-S3011A : Product video full version & ESD Simulator ESS-S3011A/GT-30RA
specifications
■ ESD Simulator Main Unit ESS-S3011A ■
Items | ESS-S3011A specifications |
Polarity | Positive or negative |
Output voltage | 0.2 to 30.0kV +/-5% (30.5kV Maximum) 0.2 to 10kV: 0.05V step, 10.0 to 30.0kV: 0.1kV step |
Repetition cycle | 0.05s to 99.9s +/-10% / Manual 0.05s to 10.0s: 0.05s step, 10.0 to 99.9s: 0.10s step |
No. of time of discharge | 1 to 60,000 times /continuous |
Discharge mode | Contac discharge / Air discharge |
Radiation level mode | Normal mode / Extra mode |
Trigger mode | Gun trigger / Main unit trigger / External trigger |
Operation panel | Color LCD / Push-buttons (Partially lighting) |
Gun holder | Standard attached (to hold the discharge gun Model GT-30RA) |
Radiation mode select switch | Extra / Normal switching function built-in |
Discharge detection | Discharge detection function in air-discharge mode equipped |
Pre-checking function | Following 3 steps function equipped (by under operation. Not the calibration but just checking) SETP1 High voltage output checking STEP2 Withstanding voltage checking STEP3 Discharge relay operation checking |
CR & Gun head checking | CR constant and gun head recognizable (with an indicator to prevent the wrong combination) |
IEC standard test mode | Contact discharge mode: 2.0, 4.0, 6.0, 8.0 kV step Air discharge mode: 2.0, 4.0, 8.0, 15.0 kV step |
Manual test mode | Contact/Air discharge mode: 0.20kV to 30.0kV Sweep function available Up to 50 units (test settings) storable |
Sequence test mode | Seamless run of the selected test sequence No. of steps per one sequence: up to 22 steps No. of test sequences: up to 20 |
Warning lamp | Lights up while the HV circuitry is on. Blinks while discharges are in progress. |
Charging capacitor and resistance | 150pF +/-10%, 330 ohm+/-10% (built into Discharge Gun GT-30RA) |
Main unit charging resistance | 10M ohm (53M ohm for combination with Discharge Gun GT-30RA) |
AUX connector | D-SUB 15 pin, female connector Connection of Warning Lamp (optional) Connection of Automatic ESD Eliminator (optional) External interlock input External trigger input |
Optical communication connector | Optic connector for PC communication (serial interface) |
Power supply/ Power consumption | 100V to 240V AC, 50Hz/60Hz +/-10% 75VA |
Included accessories | Remote controller 13-00004A, Gun holder, Instruction manual |
Dimensions and weight | (W) 270 X (H)312 X (D)295 mm Approx. 7.0kg (gun holder excluded) , Approx. 7.5kg (gun holder included) |
■ Discharge Gun GT-30RA Conforming to IEC 61000-4-2■
Items | Specifications |
Output voltage | 0.20~30.0kV ±5% (with ESS-S3011A/B3011A) 0.20~16.0kV ±5% (with ESS-L1611A) |
Discharge mode | Air discharge and contact discharge |
Discharge waveform parameters | Compliant with EN/IEC61000-4-2 |
Standard energy storage capacitor | 150 PF±10% |
Standard discharge resistor | 330ohm±10% |
Charging resistor | 43Mohm (53M ohm for combination with ESS main unit) |
Cable length | 2 m |
Dimensions | 83.4(W) x 217.2(H) x 189.3 (D) mm (Discharge tip excluded) |
Weight | Approx. 1300g (cable and high voltage connector included |
■ Discharge Gun GT-30R3302KA Conforming to ISO10605■
Items | GT-30R3302KA |
Output voltage | 0.20~30.0kV ±5% (with ESS-S3011A/B3011A) 0.20~16.0kV ±5% (with ESS-L1611A) |
Discharge mode | Air discharge and contact discharge |
Output polarity | Positive / negative |
Standard energy storage capacitor | 150 PF±10% , 330 PF ±10% |
Standard discharge resistor | 330 ohm±10% & 2K ohm ±10% |
Charging resistor | Contained in the CR unit |
Cable length | 2 m |
Charged voltage hold time | 5 seconds or more |
Dimensions | 83.3(W) x 217.2(H) x 229.3 (D) mm (Discharge tip excluded) |
Weight | Approx. 1300g (cable and high voltage connector included) |