This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.
ITEMLIST
Products Infomation
RSA306B can be used as standard for EPS-02EV3
EPS is a EMC/EMI debugging tool enabling designers to rapidly perform pre-measurement, failure point identification, and improvement efficiency confirmation in EMC/EMI countermeasure process of product design.
How does it work? The software detects locations of probes by color discrimination through camera’s image sensors*, real time analysis measured signal frequency, shows a heat map by overlapping electromagnetic field strength and real images of measured objects.
Electromagnetic Field Visualization System
Model:
EPS-02Ev3 (Small and low price version)
Maker:
NOISE LABORATORY CO.,LTD.
Features
- A real-time diagnostic tool supports EMC/EMI debugging.
- Fast visualize EMC/EMI problems.
- Enables easy comparison of countermeasures before and after.
- Capable of measurement from entire products to single components.
- Factor-editor function provides correction of antenna characteristics, cable loss and pre-amplifier.
- User friendly compact design.
- Customer supplied spectrum and probes acceptable (Please consult)
Electromagnetic Field Visualization System EPS-02Ev3
Specifications
Frequency range | 100kHz ~ 3GHz *Depends on the electromagnetic field probe specifications (The above is for ETS probes) |
Measurement unit | dBμV、dBm |
Sensor/probe | φ60 / 30 / 10mm loop coil (magnetic field), φ36mm ball (electric field), φ6mm tip (electric field) Total 5 types *Depends on electromagnetic probe specifications (Probe by ETS-Lindgren) |
Probe cable length | 2m(N(P)-BNC(P) (Coaxial connector cable) |
Data recording method | Single / Free Run / Max Hold / Max Peak Data* |
Auxiliary function | Save / load / export / comment input / factor re-read / camera image retake / Save / load / export / comment input / factor re-read / camera / image retake / up-down & right-left inversion of camera image / ghost display of camera image / Screen enlargement-reduction |
Compatible operating system | Windows 7 / 10 |
System configuration | Electromagnetic field probe (PN 7405) , BNC (P) -N (P) connector coaxial cable (02-000150A), Three Color Probe Head Cover (03-00111A), RF preamplifier (00-00019A), Spectrum analyzer, Control PC |
accessories | LAN cable, NI-GPIB-USB-HS GPIB Controller, Camera, USB cable extension 2 m for camera, Tripod for camera, Software, USB protect key, Instruction manual |
*Peak Hold: Displays the trace data with the largest peak value from the trace data measured at each measurement point.