NOISEKEN Automotive Transient Surge Simulator ISS-7600 Series | PT. NIHON DENKEI INDONESIA Jakarta
CONTENTS CONTENTS

ITEMLIST

Products Infomation

NOISEKEN Automotive Transient Surge Simulator ISS-7600 Series

conforming to ISO7637-2

Designed to meet and exceed the testing needs to ISO-7637-2 (2004), NoiseKen ISS-7600 series Automotive Transient Surge Simulator System offers flexible and productive testing facilities.

Automotive Transient Surge Simulator

Model:

ISS-7600 Series

Maker:

NOISE LABORATORY CO.,LTD.

NOISE LABORATORY CO.,LTD.

  • Highly accurate output waveforms
  • Waveforms guaranteed not only at the output terminal of each generator but also at the output terminal of the Coupling Network.
  • Capable of running either as a system or as individual generators.
  • PC Remote Control Software (ISS-7601) can control ISS-7600 through USB interface connection.
  • Supports 12V/24V/42V systems
  • 60V/50A Coupling Network
  • Up to 200A Power supply available.
  • Electric shock-free safety plugs are used for every output terminal.
  • Load resistors meeting the loading conditions (specified in Annex D of the standard)for the verification of the output characteristics optionally available.
  • Equipped with a high accuracy current monitor.  An oscilloscope allows measurement of the current waveform flowing into the DUT. Current and voltage waveforms can be examined at the same time with an oscilloscope since the current monitor output circuit is floating with respect to the SG and FG. The monitor’s frequency response characteristic is from DC to 150kHz.
  • Japanese software is also available.

Specifications

 

■  ISS-7610 Pulse 1, 2a Generator

Parameters Specifications (Pulse 1) Specifications (Pulse 2a)
Output Voltage (Us) -5 ~  -720V ±10%  ( -1V step)  5 ~  300V ±10% ( 1V step)
Output Resistance (Ri) 10 ohm, 30 ohm, 50 ohm 2 ohm, 4 ohm, 10 ohm, 30 ohm, 50 ohm
Duration (td) 50µs, 200µs, 300µs, 500µs, 1ms, 2ms 50µs, 200µs, 300µs, 500µs
Rise time (tr) 1µs: -0.5µs/+0µs
3µs: -1.5µs/+0µs
1µs: -0.5µs/+0µs
Pulse period (t1) 0.5s ~ 99.9s (0.1 step) 0.1s ~ 99.9s (0.1 step)
Pulse period (t2) 200ms
Pulse period (t3) < 100µs
COUNT 1~99900 times  7segment LED
Circuit Breaker Rated current 40A
Remote Interface Option: Optical Interface Unit Model: 07-00022A
control Software Option: Remote Control Software Model: ISS-7601
from PC Compatible OS Windows 7, Windows 10
DUT capacity DC60Vmax, 30Amax
Power supply AC100V, 110V, 120V, 200V, 220V, 240V ±10% (50/60Hz)
Operating temperature  23°C±5°C / 25~75% (No dewing shall occur.)
and humidity
Dimensions (W) 430 X (H) 200 X (D) 522 mm
(Projections excluded)
Weight Approx. 20kgs
Power consumption Approx. 260VA
Standard accessories Instruction manual, Replacement fuse (3.15A), Interlock plug, Short-circuit lead, DC Input Cable (2m) Output Cable (2m)

 

■ ISS-7630 Pulse 3a, 3b Generator

Parameters Specifications (Pulse 3a. 3b)
Output Voltage (Us) Pulse 3a – 20 ~  -350V ±10% ( -1V step)
Pulse 3b 20 ~  350V ±10%  (1V step)
Output Resistance (Ri) 50 ohm
Duration (td) 150ns±45ns
Rise time (tr) Set as 5n 5ns±1.5ns (Us=±20V~±350V)
Set<3.5ns < 3.5ns (Us=±50V~±300V)
Pulse period (t1) 10µs ~ 999µs ±10%  (1 µs step)
t4 (refer to the figures shown belown for its definition) 1ms ~ 100ms ±10% (1ms step)
t5(refer to the figures shown belown for its definition) 9ms ~ 999ms ±10% (1ms step)
Test Time Set in min 1min ~ 999 min  ±10%  (1ms step)
Set in sec 1s ~ 999 s  ±10%  (1s step)
Circuit Breaker Rated Current 40A
Interlock External input:
Control at contact point or Open Collector
L Level: 0~0.4V       H level: 2V~4V
Remote control from PC Interface Option: Optical Interface Unit Model: 07-00022A
Software Option: Remote Control Software Model: ISS-7601
Compatible OS Windows 7, Windows 10
DUT capacity DC60Vmax, 30Amax
Power supply AC100V, 110V, 120V, 200V, 220V, 240V ±10% (50/60Hz)
Operating temperature and humidity  23°C±5°C / 25~75% (No dewing shall occur.)
Dimensions (W) 430 X (H) 200 X (D) 522 mm
(Projections excluded)
Weight Approx. 17kgs
Power consumption Approx. 110VA
Standard accessories Instruction manual
Replacement Fuse (3.16A)
Interlock plug
DC Input Cable (2m)
Output cable (0.5m)
BNC conversion adapter
50 ohm coaxial cable with BNC
GND cable
Short-circuit lead (for waveform verification)

 

■ BP4610 Pulse 2b, 4 Generator

Parameters Specifications (Pulse 2b. 4)
Pulse 2b UA, Us (*) 0V  ~  60.0V ±10% ±0.5V in steps of  0.1V
Ri 0 ohm ~ 0.05 ohm
Td 0.1s, 0.2s, 0.5s, 1s, 2s, 4s ±20%
t12, tr, t6  (*) 1ms, 2ms, 5ms ±50%
Pulse 4 Ub 0V ~ 60V ±10% ±0.5V In steps of 0.1V
Us, Ua 0V ~  -Ub ±10% ±0.5V In steps of 0.1V
Ri 0 ohm ~ 0.02 ohm (Factory setting)
t7, t8, t10, t11  (*) 1ms  ~ 999ms  ±10%  In steps of 1ms
t9 0.1s ~ 99.9s ±10%  In steps of 0.1s
Dimensions (W) 430 X (H) 177 X (D) 550 mm
(Projections excluded)
Weight Approx. 26 kgs

(*) Each item can be set separately.

 

■ ISS-7650 Pulse 5a, 5b Generator

Parameters Specifications
Counter 1~ 999 Count,  7 Segment LED
Cycle Timer 30s ~ 999s , 1s step   7 Segment LED
Interlock Control by External Input, Contact Point or Open
CollectorL Level: 0V ~ 0.4V ,        H Level: 2V ~ 4V
Warning Lamp Option Model: 11-00008B
Current Monitor Output Unit 10mV/A
Characteristic Freq DC ~ 150kHz,  Approx. -3dB
Error Tolerance ±5% (DC Measure Value) ±0.8Amax (Offset) at 25°C
Withstanding Voltage DC60V (BNC Terminal Exterior: FG)
Form BNC Terminal
(Oscilloscope Wave Verification 1M ohm Input)
Circuit Breaker Rated Current 40A
Remote Control From PC Interface Option: Optical Interface Unit Model: 07-00022A
Software Option: Remote Control Software Model: ISS-7601
Compatible OS Windows 7, Windows 10
DUT capacity DC60Vmax, 30Amax
Power supply AC100V, 110V, 120V, 200V, 220V, 240V ±10% (50/60Hz)
Operating temperature and humidity  23°C±5°C / 25~75% (No dewing shall occur.)
Dimensions (W) 430 X (H) 670  X (D) 660 mm (Projections excluded)
Weight Approx. 100kgs
Power consumption Charging: Approx. 600VA,     Standby: Approx. 150VA
Standard accessories Instruction manual
Spare fuse 6.3A
Interlock plug
DC injection selection plug
Current monitor coaxial cable
DC input cable 2m
Output cable 2m
Short lead cable (for waveform verification)
Pulse 5a 12V system 24V system
Output Voltage (Us) 20V ~  100V±10% (0.5V step) 20 ~  200V±10% ( 0.5V step)
Output Resistance (Ri) 0.5 ohm ~   8 ohm (0.5 ohm step)  1 ohm ~   8 ohm (0.5 ohm step)
Duration (td) 40ms, 100ms, 200ms, 350ms,
400ms ±20%
100ms, 200ms, 350ms, 400ms
±20%
Rise time (tr) 10ms-5ms/ +0ms 10ms-5ms/+0ms
Pulse 5b 12V system 24V system
Output Voltage (Uss) 10V ~   40V ±10%  (0.1V step)
Open Voltage (Us) 100V>=Us>Uss 200V>=Us>Uss
Duration (td) Td of pulse 5b is dependent on Us, Uss and Ri settings. The same value as pulse 5a td is not available

 

■ Coupling Network ISS-7690 / System Rack ISS-7602

Parameters Specifications
DUT Capacity 60V/50A
DC Input 2 channels (DC supply/Battery)
Pulse input Pulse 1, Pulse 2a/2b, Pulse 3a/3b, Pulse 4, Pulse 5a/5b
Supply interruption test <1μs fall time
(available with DC supply interruption test only)
Current Monitor Monitoring Terminal (BNC), Output 10mV/A, DC to 150kHz
Dimensions of rack (W) 555 X (H)  1800  X (D) 790 mm (Projections excluded)

 

 

■ High Speed Bipolar Power Amplifier AS-Series

Models Specifications
AS-161-30 DC-15V-+60V
15A Max/30A peak
Frequency Response Characteristic: DC~150lHz
AS-161-60 DC-15V-+60V
30A Max/60A peak
Frequency Response Characteristic: DC~150lHz

 

Get Adobe' Reader'

To view the pdf files, the Adobe Reader from Adobe Systems is required.

Researched by Shared Research Inc.
about Nihon Denkei Co., Ltd.