This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.
ITEMLIST
Products Infomation
Beautiful waveforms, analog finish. Made in Japan at affordable prices
Bandwidth 100, 200MHz
2GS/s 4, 2 Channel
500k points
Added functionality from the DS-5400
2GS/s sampling on all models
Supports PNG transparency attributes for hard copy output
Supports averaging effective count display
Digital Oscilloscopes
Model:
DS-5400A Series
Maker:
GRAPHTEC IWATSU Test Instruments Co.,Ltd.
Line up
2GS/s compatible with 100MHz devices
Compatible with all models 2GS/s. The maximum sampling speed can be increased from 1GS/s to 2Gs/s by 2-channel coupling.
DS-5424A/5414A for 4-channel models
Usual:4 channels 1GS/s
→ When 2 channels are combined:2 channels 2GS/s
DS-5422A/5412A for 2-channel models
Usual:2 channels 1GS/s
→ When 2 channels are combined:1 channel 2GS/s
Specifications
Digital Oscilloscope “ViewGo II” DS-5400A Series Specifications
| 200MHzModel | 100MHzModel | ||||
|---|---|---|---|---|---|
| DS-5424A | DS-5422A | DS-5414A | DS-5412A | ||
| Rise time (Representative values) |
1.75ns | 3.5ns | |||
| Number of input channels | 4 | 2 | 4 | 2 | |
| Frequency bandwidth (-3dB) | 200MHz | 100MHz | |||
| Maximum sampling speed | 2GS/s (when channels are coupled), 1GS/s (when all channels are used) | ||||
| Equivalent sampling speed | 100GS/s | ||||
| Peak detection resolution | 1ns | ||||
| Averaging function | 2 to 256 times (power of 2 steps) | ||||
| Memory length | 500k point/ch (all channels) | ||||
| Vertical resolution | 8bit | ||||
| Input voltage range | 2mV/div ~ 10V/div | ||||
| Offset voltage | 2mV/div ~ 50mV/div : ±1V、50.2mV/div ~ 500mV/div : ±10V、502mV/div ~ 10V/div : ±100V | ||||
| Deskew | 0~500 ns | ||||
| DC gain accuracy | ±(1.5% +0.5% full-scale) | ||||
| Maximum input voltage | ±400 Vpeak | ||||
| Bandwidth limit filter | Analog type:20MHz,2MHz, 200kHz | ||||
| Input coupling | GND、DC 1MΩ、AC1MΩ | ||||
| Input impedance | 1MΩ±1% //20pF(DC 1MΩ) | ||||
| Probe sense | Auto search:1:1, 10:1, 100:1, 1000:1 Manual setting:1:1, 5:1, 10:1, 20:1, 50:1, 100:1, 200:1, 500:1, 1000:1, 2000:1 |
||||
| Time axis range | 2ns/div ~ 50s/div | 5ns/div ~ 50s/div | |||
| Standard probe | SS-0130R (with standard number of channels) | ||||
| Roll mode | 50ms/div ~ 50s/div(100kS/s max) | ||||
| Clock accuracy | ±10 ppm | ||||
| Power supply/power consumption | AC100~240Vrms(50/60Hz), AC100V~120V(400Hz) / 95VA(60W)max | ||||
| Dimensions/Body weight | Approx. 330Wx190Hx124D mm/Approx. 3.7kg | ||||
| Performance warranty temperature | 10 ~ 35℃ | ||||
| Operating temperature/humidity/altitude | Temperature 0 to 40°C/Humidity 5 to 80% RH ≤ 30°C (no condensation), 55% RH or less 40°C (no condensation)/Altitude 2000m or less |
||||
| Standard Accessories | Probes (one for each channel), power cord (1), front panel cover (1), manual (CD-ROM) (1), user’s guide (1) | ||||
Trigger function
| Contents | |
|---|---|
| Trigger function | Edge, number of pulses, pulse width, period, missing, TV |
| Trigger mode | AUTO, NORMAL, SINGLE, STOP |
| TV trigger (standard)/Line setting range selection/Field selection | NTSC, PAL, Custom/up to 3000/1, 2, 4, 8 |
| Pulse number trigger setting range | 1 to 9999 events |
| Pulse width trigger time setting range | 15ns~50s |
| Cycle trigger time setting range | 40ns~50s |
| Missing (dropout)Trigger time setting range | 50ns~50s |
| Trigger source | All channels, EXT (±0.5V), EXT10 (±5.0V), line |
| Trigger slope/Coupling | Positive, negative/AC, DC, high frequency removal, low frequency removal, noise removal |
Parameter measurement, cursor, zoom, math, replay
| Contents | |
|---|---|
| Parameter measurement | Maximum value, minimum value, peak value, RMS value, cycle RMS value, average value, cycle average value, top, base, top-base, rising overshoot, falling overshoot, rising time 20-80%, falling time 80-20%, rising time 10-90%, falling time 90-10%, frequency, cycle, number of pulses (positive), number of pulses (negative), pulse width (positive), pulse width (negative), duty ratio, integral, skew (positive/negative), skew @ level |
| Number of simultaneous measurements | Maximum 4 parameters |
| statistical value display | maximum value, minimum value, number of measurements |
| Cursor | Time, Amplitude, Time & Amplitude, Value at Cursor |
| Zoom | Press the Zoom button on the front panel to display the magnified waveform in a different grid |
| Math function | Addition, subtraction, multiplication, FFT(up to 8k points, rectangular, Hanning, flat top window function) |
| Rescale | a * x + b (x: input voltage, a, b: user-defined) |
| unit conversion | volt, ampere, watt, °C, no display |
| Replay | Automatic waveform recording, up to 1024 waveforms can be saved and replayed |
| Frequency counter | 6-digit |
| Interface | USB 2.0HS support (device, host), GPIB (factory option DS-576) |
| AUX interface | Connector for external option |
| Waveform data save | Save to USB memory device with binary, ASCII, Mathcad, arithmetic (ASCII), and arithmetic (Mathcad) |
| Hard copy output | Save the image to a USB memory device in TIFF, BMP, or PNG (Transparent) format or output to a PictBridge® -compatible printer |
| Calibration signal output | Square wave 1kHz, 3Vp-p |
Option
| Contents | |
|---|---|
| GPIB interface DS-576 (Factory option) |
GPIB: IEEE488.2 |
| Probe power supply DS-579 (Factory option) |
IWATSU ELECTRIC active probe power supply 2 Series |