This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.


ITEMLIST
Products Infomation

A tester simulatively generates "High energy induced lightning noise" which induced to distribution lines or communication lines by ground potential fluctuation caused by lightning strikes.
Lightning Surge Simulator
Model:
LSS-6330 series
Maker:
NOISE LABORATORY CO.,LTD.
Features
- Conforming to IEC 61000-4-5 Ed.3, IEC61000-4-12 Ed.3(RINGWAVE 100kHz)and ANSI IEEE62-45(2002)
- Pre-checking function simplifies start-up inspection works.
- Voltage and current monitors enable status monitoring during noise applied to EUT.
- Large LCD operation panel improve visibility and operability.
- MPU control function simplifies continuous testing, enables automatic surge-out, waveform-switching and polarity switching.
- Equipped with both manual and program mode to simplify test condition setting. Manual mode: for standard and single-shot testing. Program mode: for different testing in succession.
- Interlocking function provides excellent safety.
- Standardly equipped waveform checking terminals provide easy output waveform checking with existing oscilloscope and BNC cables.
- Isolation transformer available for safety protection for superimposing circuit current leakage and back surge to power source.(Option)
Lightning Surge Simulator LSS-6330 series
Specification
■ Surge generator unit LSS-6330-A20 / -B63 both applicable ■
Item | Specification | Note | |
Coupling Surge Waveform | 1.2/50μs-8/20μs combination 10/700μs-5/320μs combination RING WAVE |
||
1.2/50μs-8/20μs combination |
Output voltage(open circuit) | 0.5kV-6.7kV ±10% | Coupling circuit: 18μF Cable length: 0.5m on one side Line input side open |
Front time voltage waveform / Duration | 1.2μs ±30% / 50μs ±20% | ||
Output current(short circuit) | 250A- 3350A ±10% | ||
Front time current waveform / Duration | 8μs ±20%/ 20μs ±20% | ||
10/700 μs-5/320μs combination |
Output voltage(open circuit) | 0.5kV-6.7kV ±10% | Cable length: 0.5m on one side |
Front time voltage waveform / Duration | 10μs ±30%/ 700μ s±20% | ||
Output current(short circuit) | 12.5A-167.5A ±10% | ||
Front time current waveform / Duration | 5μs ±20% / 320μs ±20% | ||
RING WAVE | Output voltage(open circuit) | 0.25kV-6.6kV ±10% | Cable length: 0.5m on one side |
Front time voltage waveform | 0.5μs ±30% | ||
Frequency | 100kHz ±10% | ||
Attenuation | Pk2 = 40% < Pk1 < 110%Pk2 = 40% < Pk1 < 110% | ||
Pk3 = 40% < Pk2 < 80%Pk3 = 40% < Pk2 < 80% | |||
Pk4 = 40% < Pk3 < 80% | |||
Output current(short circuit) | 8.3-550A±10% | ||
Front time current waveform | 0.2-1μs | ||
Palarity | Positive / Negative | ||
Output impedance | 2Ω±10% | 1.2/50μs waveform | |
40Ω±10% | 10/700μs waveform | ||
12Ω±20%、30Ω±20% | RING (selective) | ||
Surge generation circuit | Floating | ||
Minimum charging time | 0.0kV-4.0kV:5 s、 4.1kV-6.7kV:10 s | 1.2/50μs waveform | |
0.0kV-4.0kV:10 s、 4.1kV-6.7kV:15 s | 10/700μs waveform | ||
0.0kV-4.0kV:1 s、 4.1kV-6.6kV:3 s | RING WAVE | ||
Communication | RS-232C (Optical connector), Bluetooth | Option | |
External CDN control | |||
Emergency stop | Push-lock(Test STOP, High voltage OFF, EUT switch SHUT OFF) | ||
Interlock function | External connection status detection | ||
Emergency lamp | Red LED blinking after start the tests | ||
Emergency lamp connector | Equiped with emergency lamp connectors. Lamp blinking after start the tests. | 3ports | |
EUT Fail | 3 ports | ||
Voltage monitor | BNC output、2000V/V ±10% | Simplified open circuit surge out checking | |
Current monitor | BNC output、1000A/V ±10% | Simplified short circuit surge out checking | |
Phase angle control | 0°-360°±10° | Operates at EUT power supply AC90V min. & 50Hz / 60Hz ± 10% | |
Trigger input | Asynchronous, AC line synchronous 0°-360° / 1° step、external input | ||
Drive power supply | AC100V-AC240V ±10% 50Hz / 60Hz ±10% | ||
Operating environment | Temperature: 15-35℃ Humidity: 25-75%RH |
||
Dimensions/ Weight | W430×H371×D530 mm / Approx. 55kgs |
■ Superimposed Output Section LSS-6330-A20 ■
Item | Specification | Note | |
Coupling Surge Waveform | 1.2/50μs-8/20μs combination, RING WAVE | ||
1.2/50μs-8/20μs combination |
Output voltage | 0.5kV-6.7kV ±10% | Coupling circuit: 18μF Cable length: 0.5m on one side Line input side open |
Front time/ Duration | 1.2μs ±30% / 50μs ±20% | ||
Short-circuit current | 250A-3350A ±10% | ||
Front time/ Duration | 8μs ±20%/ 20μs ±20% | ||
Output voltage | 0.5kV-6.7kV ±10% | Coupling circuit: 10Ω+9μF Cable length: 0.5m on one side Line input side open |
|
Front time/ Duration | 1.2μs ±30% / 50μs +10μs /-25μs | ||
Short-circuit current | 41.6A-558A ±10% | ||
Front time/ Duration | 2.5μs ±30%/ 25μs ±30% | ||
RING WAVE | Output voltage | 0.25kV-6.6kV ±10% | Coupling circuit:4.5μF Cable length: 0.5m on one side Line input side open |
Front time | 0.5μs ±30% | ||
Frequency | 100kHz ±10% | ||
Attenuation rate | Pk2 = 40% < Pk1 < 110%Pk2 = 40% < Pk1 < 110% | ||
Pk3 = 40% < Pk2 < 80%Pk3 = 40% < Pk2 < 80% | |||
Pk4 = 40% < Pk3 < 80% | |||
Short-circuit current | 8.3 ~ 550A±10% | ||
Front time | 0.2 ~ 1μs | ||
EUT power capacity | AC240V/20A MAX 50/60Hz、DC125V/20A MAX | ||
Decoupling coil | 1.5mH | ||
Voltage drop | Less than 10% of rated voltage when rated current is applied | At the output terminal of the AC superposition section | |
Residual voltage | 15% or less of the applied surge voltage or twice or less of the rated voltage (peak value) of the power supply line |
■ Superimposed Output Section LSS-6330-B63 ■
Item | Specificaion | Note | |
Coupling Surge Waveform | 1.2/50μs-8/20μs combination, RING WAVE | ||
1.2/50μs-8/20μs combination |
Output voltage | 0.5kV-6.7kV ±10% | Coupling circuit: 18μF Cable length: 0.5m on one side Line input side open |
Front time/ Duration | 1.2μs ±30% / 50μs ±20% | ||
Short-circuit current | 250A-3350A ±10% | ||
Front time/ Duration | 8μs ±20% / 20μs ±20% | ||
Output voltage | 0.5kV-6.7kV ±10% | Coupling circuit: 10Ω+9μF Cable length: 0.5m on one side Line input side open |
|
Front time/ Duration | 1.2μs ±30%/ 50μs +10μs /-25μs | ||
Short-circuit current | 41.6A-558A ±10% | ||
Front time/ Duration | 2.5μs ±30%/ 25μs ±30% | ||
RING WAVE | Open voltage | 0.25kV-6.6kV ±10% | Counpling circuit: 4.5μF Cable length: 0.5m on one side Line input side open |
Front time | 0.5μs ±30% | ||
Frequency | 100kHz ±10% | ||
Attenuation rate | Pk2 = 40% < Pk1 < 110% Pk3 = 40% < Pk2 < 80% Pk4 = 40% < Pk3 < 80% |
||
Short-circuit current | 8.3-550A±10% | ||
Front time | 0.2-1μs | ||
EUT power capacity | AC600V/63A MAX 50/60Hz、DC125V/63A MAX | ||
Decoupling coil | 1.5mH | ||
Voltage drop | Less than 10% of rated voltage when rated current is applied | At the output terminal of the AC superposition section | |
Residual voltage | 15% or less of the applied surge voltage or twice or less of the rated voltage (peak value) of the power supply line | ||
Phase angle control | 0°-360° ±10° | Operates at EUT power supply AC90V min. & 50Hz / 60Hz ± 10% | |
Drive power supply | AC100V- AC240V ±10% 50Hz / 60Hz ±10% | ||
Operating environment | Temperature:15-35℃ Humidity: 25-75%RH |
||
Dimensions | W430 × H695 × D686 mm |
*Requires an isolation transformer separately.