This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.


ITEMLIST
Products Infomation

Specializing in simple operation and simple specifications as the definitive low-cost power supply.
The lineup includes five models with output capacities of 500VA, 1kVA, 2kVA, 3kVA, and 5kVA. This is an AC power supply that can be used for a wide range of applications, from home appliances to aircraft power supplies.
AC source 6900S Series
Maker:
KEISOKU GIKEN
Feature
Supports wide variable range
Supports output from voltage 0 to 310V and frequency from 40 to 450Hz. It can be used in a wide range of situations, from white goods such as air conditioners, washing machines, refrigerators, and vacuum cleaners to aircraft power supplies.
Simultaneous measurement of 4 values
Frequency, voltage, current and power factor (or power) can be measured simultaneously like a power meter. In addition, we have adopted a large green LED with high visibility to make it easier to see.
Easy operation with direct keys
Other than the system keys, the buttons only call certain functions. Anyone can operate it easily without reading the instruction manual.

Resistant to inrush current
Inrush current can be supplied up to 4 times the specification. It can withstand repeated crest factors up to three times the specification.

Specification
Type name | 6905S | 6910S | 6920S | 6930S | 6950S | ||
---|---|---|---|---|---|---|---|
input
|
|||||||
number of phases | 1Ø | ||||||
Input method | inlet | terminal | |||||
Voltage | AC 100/AC 200 V±10%, AC 110/AC 220 V±10% (can be specified) |
AC 200 V±10%, AC 220 V±10% (can be specified) | |||||
frequency | 47-63Hz | ||||||
maximum current | 10.0A (90V) / 5.0A (180V) |
20.0A (90V) / 10.0A (180V) |
20.0A (180V) | 30.0A (180V) | 50.0A (180V) | ||
Power factor | 0.67 or more | ||||||
AC output
|
|||||||
power rating | 500 VA | 1000 VA | 2000 VA | 3000 VA | 5000VA (*1) | ||
Maximum current (rms) (*2) | 0 – 155V | 4.6A (at 110V) |
9.2A (at 110V) |
18.4A (at 110V) |
27.6A (at 110V) |
46.0A (at 110V) |
|
0 – 310V | 2.3A (at 220V) |
4.6A (at 220V) |
9.2A (at 220V) |
13.8A (at 220V) |
23.0A (at 220V) |
||
Number of phases/wires | 1Ø/2W | ||||||
Total harmonic distortion (THD) | <0.3% (at 110/220 V & 50/60 Hz resistive load) <0.5% at 40 – 100 Hz, <1% at 101 – 450 Hz (at resistive load) |
||||||
crest factor | 3 or more | ||||||
line regulation | ±0.1V | ||||||
load change | ±(0.5 % of output + 0.5 V) (at resistive load) | ||||||
response time | 400 usec or less | ||||||
setting
|
|||||||
Voltage | range | 0 – 310 V, 155/310 V autoranging | |||||
resolution | 0.1V | ||||||
Accuracy | ±(1% of reading + 0.1% of fs .) | ±(1% of reading + 0.2% of fs .) | |||||
frequency | range | 0.0 – 450.0Hz | |||||
resolution | 0.1Hz(40.0-99.9Hz), 1Hz(100-450Hz) | ||||||
Accuracy | ±0.03% of setting | ||||||
AC/DC measurement
|
|||||||
frequency | range | 0.0 – 450.0Hz | |||||
resolution | 0.1Hz | ||||||
Accuracy | ±0.1Hz | ||||||
Voltage (AC & DC) |
range | 0.0 – 400.0V | |||||
resolution | 0.1V | ||||||
Accuracy | ±(1% of reading + 0.1% fs ) | ±(1% of reading + 0.2% fs ) | |||||
Current (rms) |
range | L. | 0.005 – 0.600A | 0.005 – 1.200A | 0.005 – 2.400A | – | – |
H. | 0.50 – 6.50A | 1.00 – 13.00A | 2.00 – 26.00A | 0.05 – 39.00A | 0.05 – 65.00A | ||
resolution | L. | 0.001A | – | – | |||
H. | 0.01A | ||||||
Accuracy | L. | ±(1 % of reading + 0.005 A) at 5 V or higher | – | – | |||
H. | ±(1% of reading + 0.05A) | ||||||
electric power | range | L. | 0.0 – 60W | 0.0 – 120W | 0.0 – 240W | – | – |
H. | 50-650W | 100-1300W | 200-2600W | 0 – 3900W | 0-6500W | ||
resolution | L. | 0.1W | – | – | |||
H. | 1W | ||||||
Accuracy (*3) | L. | ±(2% of reading +1.5W) at PF>=0.2 & Voltage >5V |
±(2% of reading +3W) at PF>=0.2 & Voltage >5V | – | – | ||
H. | ±(2% of reading +5W) at PF>=0.2 & Voltage >5V |
±(2% of reading +10W) at PF>=0.2 & Voltage >5V |
±(2% of reading +5W) at PF>=0.2 & Voltage >5V |
||||
Power factor | range | 0-1.000 | |||||
resolution | 0.001 | ||||||
Accuracy | First 3 digits of W / VA calculation | ||||||
General specifications
|
|||||||
memory | 3 memories (M1, M2, M3) | ||||||
display | Green LED | ||||||
Overcurrent foldback | On/Off | ||||||
efficiency | 78% or more | 80 and more | |||||
protective function | Overcurrent, overvoltage, overpower, overheat, short circuit, and alarm | ||||||
Proofreading | Front panel calibration | ||||||
Withstand voltage | AC1500V/1 minute (between input and FG, between input and load constant terminals) | ||||||
insulation resistance | DC500V/30MΩ or more (between input and FG, between input and load constant terminal) | ||||||
usage environment | Indoor use / 2000 m or less above sea level | ||||||
Operating environment | Temperature: 0 to +40°C, Humidity: 20 to 85% RH (no condensation) | ||||||
Storage environment | Temperature: -20 to +60°C, Humidity: 20 to 85% RH (non-condensing) | ||||||
External dimensions (W×H×D, mm) | 430x89x300 | 430x89x400 | 430x89x500 | 430x222x500 | 430x222x500 | ||
mass | 12.5kg | 18.2kg | 30 kg | 57kg | 65 kg |
*1 : Can be used continuously at PF 0.8. *2 : Operating voltage: 110 V / 220 V *3 : When the power factor is 0.2 or more and the output voltage exceeds 5 V (6905S, 6910S, 6920S)