HIOKI Power Analyzer PW6001 | PT. NIHON DENKEI INDONESIA Jakarta
CONTENTS CONTENTS

ITEMLIST

Products Infomation

HIOKI Power Analyzer PW6001

DC, 0.1 Hz to 2 MHz, 3-phase 4-wire, High Precision Power Analyzer for Motor and Inverter Efficiency Analysis

Hioki benchtop power meters and power analyzers are best in class power measuring instruments for measuring single to three-phase lines with a high degree of precision and accuracy. The PW6001 is Hioki’s flagship power analyzer, featuring high accuracy, wide band, and high stability for measuring electrical power from DC to inverter frequencies, providing maximum of 12 channels (*1) to support single- and three-phase inverter motor system measurements and next generation devices such as silicon-carbide (SiC) inverters.

Power Analyzer

Model:

PW6001

Maker:

HIOKI

Download Materials

Key Features

Exclusive current sensor phase shift function lets you maintain accuracy even in high frequency, low power factor applications

Basic accuracy of ±0.02% (*2) for power measurement

High noise resistance and stability (80 dB/100 kHz CMRR, ±0.01%/°C temperature characteristics)

Accurate measurement even when the load is characterized by large fluctuations; TrueHD 18-bit resolution

10 ms data refresh while maintaining maximum accuracy (*3)

DC accuracy of ±0.07%, which is key for stable, accurate efficiency measurement

Wide frequency bandwidth of DC, or 0.1 Hz to 2 MHz

Achieve true frequency analysis with high-speed 5MS/s sampling (18 bit)

Synchronize 2 units for up to 12 channels (*4) in real time

Special triggers to enable waveform analysis and motor analysis without the need for an oscilloscope

Wideband harmonic analysis up to the 100th order with a 1.5 MHz band

Send measured values to Hioki data loggers using a Bluetooth® wireless technology compatible adapter (LR8410 Link-compatible products), Ver. 2.0 and later

Fitur

  • Current Sensor Phase Shift

  • 0.1 Hz to 2 MHz frequency bandwidth

  • High-speed sampling of 5 MS/s for true frequency analysis

  • Fast, simultaneous calculation functions achieved with Power Analysis Engine II

  • Strengthened resistance to noise and temperature fluctuations in the absolute pursuit of measurement stability

  • Analyze waveforms without an oscilloscope

  • Harmonic analysis up to 1.5 MHz

  • FFT analysis of target waveforms

  • Digital LPF for displaying the waveform you want to view

  • Seamless operability

  • One-touch settings take you to measurement immediately

  • DC accuracy is indispensable for achieving correct efficiency measurements

  • Specially designed for current sensors to achieve highly precise measurement

  • High-accuracy clamp current sensor

  • Get a combined accuracy of ±0.075% rdg. with CURRENT BOX PW9100

  • Wideband current probes supported

  • CT6904, The optimal device for testing large current inverters

  • PC Communication Software – PW Communicator

  • Remote control via LAN

  • Diverse motor analysis functions

  • SiC measurement achieved with high resolution

  • Advanced electrical angle measurement function

  • Display any calculation result in real-time

  • Power conditioner testing

  • Build a 12-channel power meter using “numerical synchronization”

  • Simply transfer waveforms with “waveform synchronization”

Spesifikasi

Measurement line type
Single-phase 2-wire, single-phase 3-wire, three-phase 3-wire, three-phase 4-wire
Number of input channels
Max. 6 channels; each input unit provides 1 channel for simultaneous voltage and current input
(Voltage measurement unit: Photoisolated input, resistance voltage divider, Current measurement unit: Isolated input from current sensor)
Measurement items
Voltage (U), current (I), active power (P), apparent power (S), reactive power (Q), power factor (λ), phase angle (φ), frequency (f), efficiency (η), loss (Loss), voltage ripple factor (Urf), current ripple factor (Irf), current integration (Ih), power integration (WP), voltage peak (Upk), current peak (Ipk)
Harmonic measurement: Harmonic active power, select calculation order
from 2nd order to 100th order
Waveform recording: Voltage and current waveforms/ Motor pulse: Always 5 MS/s
Motor waveforms: Always 50 kS/s, 16 bits
Recording capacity: 1 Mword × ((voltage + current) × number of channels + motor
waveforms)
Motor analysis (PW6001-11 to -16 only): Voltage, Torque, Rotation, Frequency, Slip, or Motor output
Measurement range
Voltage range: 6 to 1500 V, 8 ranges
Current range (Probe 1) : 400 mA to 1 kA (depends on current sensor)
Current range (Probe 2) : 100 mA to 50 kA (depends on current sensor)
Power range: 2.40000W to 4.50000MW (depends on combination of voltage and current range)
Frequency range: 0.1 Hz to 2 MHz
Basic accuracy Voltage: ±0.02 % rdg. ±0.02 % f.s.
Current: ±0.02 % rdg. ±0.02 % f.s. + current sensor accuracy
Active power: ±0.02 % rdg. ±0.03 % f.s. + current sensor accuracy
Synchronization frequency range
Power measurement: 0.1 Hz to 2 MHz
Harmonic measurement: 45 Hz to 66 Hz (IEC standard mode), 0.1 Hz to 300 kHz (Wideband mode)
Frequency band DC, 0.1 Hz to 2 MHz
Data update rate
Power measurement: 10 ms/ 50 ms/ 200 ms
Harmonic measurement: 200 ms (IEC standard mode), 50 ms (Wideband mode
Data save interval
OFF, 10 msec to 500 msec, 1 sec to 30 sec, 1 minute to 60 minutes
User-selected from all measured values, including harmonic measured values,
Specified measured values can be saved in internal memory or USB flash drive
External interfaces
USB (memory), LAN, GP-IB, RS-232C (for communication/LR8410 link), External control ,Synchronization control
Logger connectivity
Sends measured values wirelessly to logger by using a Bluetooth® wireless technology serial conversion adapter. (Supported devices: Hioki LR8410 Link-compatible loggers), Ver. 2.0 and later
Power supply 100 to 240 V AC, 50/60 Hz, 200 VA max
Dimensions and mass
430 mm (16.93 in)W × 177 mm (6.97 in)H × 450 mm (17.72 in)D, 14 kg (49.4 oz) (PW6001-16)
Accessories
Instruction Manual ×1, Power cord ×1, D-sub connector × 1 (PW6001-1x only)

Get Adobe' Reader'

To view the pdf files, the Adobe Reader from Adobe Systems is required.

Researched by Shared Research Inc.
about Nihon Denkei Co., Ltd.