This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.


ITEMLIST
Products Infomation

Model All-in-one yang menggabungkan withstand voltage dan insulation resistance (AC/DC)
Penguji keamanan listrik Hioki dirancang untuk insulation resistance dan pengujian voltage withstand perangkat dan komponen listrik sesuai dengan berbagai standar keselamatan. 3153 adalah automatic insulation dan penguji AC/DC voltage withstanding yang sepenuhnya mendukung pengujian otomatis.
Automatic Insulation / Withstanding HiTESTER 3153
Model:
3153
Maker:
HIOKI
Fitur
-
Isolasi yang dapat diprogram (50 V hingga 1200 V DC) dan pengujian kekuatan dielektrik (AC/DC)
-
Memprogram hingga 32 file jenis pengujian, titik uji (50 langkah), dan pengaturan pengukuran
-
Pemindai opsional untuk pengujian otomatis multipoint
-
Menggunakan metode PWM untuk menghasilkan uji tegangan yang akurat yang tidak bergantung pada tegangan suplai
-
Fungsi pengatur waktu ramp untuk menambah atau mengurangi tegangan yang diberikan selama pengujian kekuatan dielektrik pada waktu yang ditentukan pengguna
Spesifikasi
Basic Specifications
Functions
|
Program up to 32 files of 50 step test settings.
|
10 sets each of dielectric strength and insulation test settings, hold, buzzer
|
|
Monitor functions |
Output voltage, detected current, measured resistance, Refresh rate: 2 times / s
|
Power supply |
100 to 120 V, 200 to 240 V AC, (50/60 Hz), 1000 VA max.
|
Dimensions and mass |
320 mm (12.60 in) W x 155 mm (6.10 in) H x 480 mm (18.9 in) D, 18 kg (634.9 oz)
|
Accessories |
HV Test Lead 9615 (high voltage side and return, 1 each) × 1, Power cord × 1, Instruction manual × 1, Spare fuse × 1
|
[Withstanding test] | |
Testing voltage AC / DC |
0.2 kV to 5.00 kV AC, 500 VA (max. 30 minutes), 0.2 kV to 5.00 kV DC, 50 VA (continuance)
|
Voltage setting | Digital setting (0.01 kV setting resolution) |
Waveform / Frequency |
Sine wave (5% or less distortion, unloaded), 50/60 Hz selectable
|
Current measurement |
0.01 mA to 100.0 mA, Average rectified display (Digital)
|
Measurement range |
10 mA (0.01 mA resolution), 100 mA (0.1 mA resolution)
|
Voltmeter |
Digital: accuracy ± 1.5% fs (fs = 5.00 kV) (Average rectified display)
|
Decision method | Window comparison (digital settings) |
[Insulation test] | |
Rated testing voltage | 50 to 1,200 V DC (in 1 V steps) |
Rated testing current | 1 mA, Short-circuit current: 200 mA or less |
Measurement range / accuracy |
0.10 to 9999 MΩ, 4 ranges, ± 4% rdg. (Representative values for 0.5 MΩ to 1,000 MΩ)
|
Decision method | Window comparison (digital settings) |
[Timer] |
* Test times may differ from set timer times depending on the load.
|
Setting range | 0.3 to 999 s |
Ramp / delay |
Testing voltage ramp-up, or down, Insulation test delay: 0.1 to 99.9 s
|