CONTENTS CONTENTS

ITEMLIST

Products Infomation

ETAC HIFLEX NEO-ES

Internal dimension (WxHxDmm)
Temp./humid. range 500×350×350 (500×350×350)×2 (500×350×350)×3 (600×600×500)×2
−40°C〜+100°C[+150°C]
20%RH〜98%RH
SXN401 SXN402 SXN403 SXN412
−40°C〜+100°C[+150°C] SLN401 SLN402 SLN403 SLN412

Environmental Testing Chamber|Low-temperature Constant-temperature and Humidity Chamber

The HIFLEX NEO-ES is a low-temperature, constant-temperature/humidity chamber that combines an overwhelmingly space-saving design with high basic performance. It is widely used in R&D and quality assurance as a next-generation constant-temperature/humidity chamber that reduces environmental impact while requiring up to 80% less installation space than conventional models.

Temperature and Humidity Test Chamber

Model:

HIFLEX NEO-ES

Maker:

Kusumoto Chemicals, Ltd.

Features

High temperature and humidity characteristics
Shares components with the high-end HIFLEX NEO-E model to achieve stable temperature and humidity characteristics. Capable of humidification operation up to 98%RH, it can handle a wide range of testing conditions.
 
Powerful sirocco fan
A sirocco fan with large air volume and high air pressure is employed. Even with specimens installed, uniform distribution performance within the chamber is ensured.
 
DC inverter controlled air-cooled rotary chiller
Equipped with DC inverter controlled air-cooled rotary chiller. Refrigeration system efficiency
Optimized refrigeration capacity by unique refrigerant flow control using an electronic expansion valve. Guaranteed temperatures up to -40°C. The test environment is stabilized and power consumption is drastically reduced.
 
Ambient operating temperature
It retains robustness to reach the minimum temperature (-40°C) even when the ambient temperature is +35°C.
 
Humidified water sterilizer (optional)
UV irradiation sterilization lamps are used to inhibit the growth of bacteria, preventing problems caused by sliminess and water stains in the piping system. This improves the reliability of water circuits.

Specifications

model (e.g. of a vehicle) SXN401-E SXN402-E SXN403-E SXN412-E SLN401-E SLN402-E SLN403-E SLN412-E
Temperature range -40C to +100C
Humidity range 20%RH to 98%RH
Temperature rise time Within 35 minutes-40C to +100C
Temperature fall time Within 55 minutes+20C to -40C Within 50 minutes+20C to -40C Within 55 minutes+20C to -40C Within 50 minutes+20C to -40C
Temperature change rate (rise) 4.0C/min-26C to +86C
Temperature change rate (descending) 2.5C/min+86C to -26C 3.0C/min+86C to -26C 2.5C/min+86C to -26C 3.0C/min+86C to -26C
Temperature and humidity fluctuations }0.3C/}2.5%RH }0.3C
Temperature and humidity gradient 3.0 in temperature operationb2.0/5.0%RH in temperature/humidity operation During temperature operation 3.0C
Space temperature and humidity deviation 2.5 during temperature operationb1.5/5.0%RH during temperature/humidity operation During temperature operation 2.5C
Operable ambient temperature range +5C to +40C
Internal dimensions (W x H x D mm) 500 x 350 x 350 (500 x 350 x 350) x 2 (500~350~350)~3 (600 x 600 x 500) x 2 500 x 350 x 350 (500 x 350 x 350) x 2 (500~350~350)~3 (600 x 600 x 500) x 2
Content (liter) 61 61 x 2 61 x 3 180 x 2 61 61 x 2 61 x 3 180 x 2
External dimensions (W x H x D mm) 660 x 1285 x 1040 660 x 1885 x 1040 660 x 1955 x 1375 760 x 1855 x 1645 660 x 1285 x 1040 660 x 1885 x 1040 660 x 1955 x 1375 760 x 1855 x 1645
Mass (kg) 190 330 500 475 185 325 495 470
Exterior Steel Plates bonder steel sheet(Baked finish)
Inner tank steel plate Stainless steel plate(SUS304)
ventilator sirocco fan
refrigerator DC inverter controlled air-cooled rotary chiller
refrigerant R-448A
Heating Heater Nichrome Strip Heaters
humidifier sheathed heater(SUS316L)
cooler Plate Fin Coil
Control Sensors JIS C1604 3-wire resistance thermometer Pt100
Control method PID control
Display method LED indication
Display resolution 0.1C/1%rh 0.1C
Setting method Key-in method using the main unitfs display unit / input method using Smart Connect (optional) or a terminal equipped with a Web browser
Ethernet 10BASE-T/100BASE-TX AUTO-MDIX compliant RJ45 connector x 1 channel
USB USB2.0 TYPE A connector x 1 channel
memory capacity 8GB
power (button on TV, etc.) AC200V 3 50/60Hz Voltage fluctuation range }10% Class D grounding
humidified water Ion-exchanged water or pure water, etc.(0.1 to 10 S/cm)
Maximum load current (A) 15 30 45 46 9 18 27 32
Operating current (A) 11 22 33 34 7 14 21 26
Exhaust heat (kW) 0.62 to 3.6 1.24-7.2 1.86-10.8 1.0-9.6 0.62 to 3.6 1.24-7.2 1.86-10.8 1.0-9.6
safeguard Main power leakage circuit breaker, fan motor overload relay, temperature overload protection device, refrigerator pressure switch, refrigerator overload relay, refrigerator overheat protection device, reverse phase detector, heating heater overload protection fuse, control circuit overload protection fuse, sensor disconnection detection function, temperature (humidity) upper/lower limit alarm function, power failure notification alarm, Filter cleaning alarm, Empty heating preventer, Humidifier heater overload protection fuse, Wick drying alarm, Water supply tank water level low alarm, Circuit protection ground-fault circuit breaker, Inverter abnormality detection function Main power leakage circuit breaker, fan motor overload relay, over-temperature protection device, refrigerator pressure switch, refrigerator overload relay, refrigerator overheat protection device, reverse phase detector, heating heater overload protection fuse, control circuit overload protection fuse, sensor disconnection detection function, upper and lower temperature limit alarm function, power failure notification alarm, filter cleaning alarm, circuit protection earth leakage circuit breaker, inverter error detection function
Ancillary Functions Memory backup function, pause function, monitor function, self-diagnostic function, power failure return protection function, instantaneous power failure retention function, external alarm output function, test termination output function, EUT power supply interlock function, auto-start/timer function, humidification delay function, standby operation function at room temperature Memory backup function, pause function, monitor function, self-diagnostic function, power failure return protection function, instantaneous power failure retention function, external alarm output function, test termination output function, EUT power supply interlock function, auto-start/timer function, standby operation function at room temperature
body (of a machine) Square measurement hole (100 x 30 mm, 2 locations on left and right sides), caster adjuster, dust filter for refrigerator condenser Square measurement hole (100 x 30 mm, 2 locations on left and right sides), caster adjuster, dust filter for refrigerator condenser
accessory Wick gauze (12 wicks/tank), silicon stopper for square measurement hole (2 stoppers/tank), adjuster fixture (4 fixtures/unit, depending on model), key for door latch (2 keys/tank), instruction manual (1 copy), water tank (401, 402: 10L, 403, 412: 20L, all models 1 tank/unit), certificate of inspection acceptance Silicone plugs for square measurement holes (2/tank), adjuster fixture (4/unit, depending on model), keys for door latches (2/tank), instruction manual (1 copy), inspection certificate

Get Adobe' Reader'

To view the pdf files, the Adobe Reader from Adobe Systems is required.

Researched by Shared Research Inc.
about Nihon Denkei Co., Ltd.