KIKUSUI Ultra-Compact AC/DC Programmable Power Supplies PCR-WEA/WEA2 Series

More power, more speed, more freedom!

The PCR-WEA/WEA2 is a series of multifunctional switching AC power supplies that combines accurate, high-power output with an ultra-compact design. The 15 model line-up ranges from 1 kVA to 36 kVA AC/DC with single & 3-phase variable output from 6 kVA and up. The PCR-WEA2R also features a regenerative mode that can drastically reduce power consumption and cut operating costs.

The PCR-WEA2/WEA2R also supports parallel operation up to maximum of three-phase 540 kVA for large-scale test systems. Output frequency up to 5 kHz is also available with all models, which is critical for AC applications in avionic industries.

Ultra-Compact AC/DC Programmable Power Supplies

Model:

PCR-WEA/WEA2 Series

Maker:

KIKUSUI ELECTRONICS CORPORATION

Download Materials

Features

  • Compact size: 6 kVA in 6U (PCR6000WEA2/PCR6000WEA2R)
  • Up to 36 kVA in a Single Unit
  • AC output *1: Single-phase/Single-phase three-wire/Three-phase
    DC output: +/-, 100% of rated power
  • 100% Regenerative-power capability
  • Expandable up to three-phase 540 kVA *2
  • Flexible digital interface: LAN (LXI), USB, RS232C, GPIB (option)
    Power line disturbance simulation features
  • Sequence function
  • External analog, digital control function (standard)
  • Power-saving function
  • Output frequency up to 5 kHz
  • Output rating: AC 0 to 320 Vrms, DC 0 to ±452 V

 

*1 For 3 kVA or more, the multi-type can switch between single-phase, single-phase 3-wire, and threephase output (PCR-WEA2). *2 Please contact us if you wish to operate more than 4 units in parallel

Line up

AC mode output rating

Model Phase Power capacity[VA] Phase voltage[V] Max. current (L/H range)[A]※1 Frequency[Hz]
PCR1000WEA Single phase 1k (The spec guaranteed voltage range)
1 to 160/ 2 to 320
(L/H output range)

(Voltage setting range)
0 to 161.0/ 0 to 322.0

10 / 5 1 to 5000
PCR2000WEA Single phase 2k 20 / 10
Single phase 3k 30 / 15
Three-phase 10 / 5
Single-phase Three-wire 2k
PCR6000WEA2R

PCR6000WEA2
Single phase 6k 60 / 30
Three-phase 20 / 10
Single-phase Three-wire 4k
PCR12000WEA2R

PCR12000WEA2
Single phase 12k 120 / 60
Three-phase 40 / 20
Single-phase Three-wire 8k
PCR18000WEA2R

PCR18000WEA2
Single phase 18k 180 / 90
Three-phase 60 / 30
Single-phase Three-wire 12k
PCR24000WEA2R

PCR24000WEA2
Single phase 24k 240 / 120
Three-phase 80 / 40
Single-phase Three-wire 16k
PCR30000WEA2R

PCR30000WEA2
Single phase 30k 300 / 150
Three-phase 100 / 50
Single-phase Three-wire 20k
PCR36000WEA2R

PCR36000WEA2
Single phase 36k 360 / 180
Three-phase 120 / 60
Single-phase Three-wire 24k

DC mode output rating

Model Power capacity[W] Voltage (nominal)[V] Max. current (L/H range)[A]※2
PCR1000WEA 1k (The spec guaranteed voltage range)
±1.4〜 ±226 / ±2.8〜 ±452
(L/H output range)

(Voltage setting range)
-227.5 〜 +227.5 / -455.0 〜 +455.0

10 / 5
PCR2000WEA 2k 20 / 10
PCR3000WEA2 3K 30 / 15
PCR6000WEA2R

PCR6000WEA2
6k 60 / 30
PCR12000WEA2R

PCR12000WEA2
12k 120 / 60
PCR18000WEA2R

PCR18000WEA2
18k 180 / 90
PCR24000WEA2R

PCR24000WEA2
24k 240 / 120
PCR30000WEA2R

PCR30000WEA2
30k 300 / 150
PCR36000WEA2R

PCR36000WEA2
36k 360 / 180

Input rating (AC rms)

Model Phase Voltage (nominal)[V] Apparent power[kVA or less] Current[A or less]
PCR1000WEA Single phase 100 to 120, 200 to 240 1.4 17 / 8.5
PCR2000WEA Single phase 100 to 120, 200 to 240 2.7 32 / 16
PCR3000WEA2 Single phase 100 to 120, 200 to 240 4 48 / 24
PCR6000WEA2 3-phase 4-wire 400 V Line voltage 380 to 480 7.8 14
PCR12000WEA2 3-phase 4-wire 400 V Line voltage 380 to 480 15.6 28
PCR18000WEA2 3-phase 4-wire 400 V Line voltage 380 to 480 23.4 42
PCR24000WEA2 3-phase 4-wire 400 V Line voltage 380 to 480 31.2 56
PCR30000WEA2 3-phase 4-wire 400 V Line voltage 380 to 480 39 70
PCR36000WEA2 3-phase 4-wire 400 V Line voltage 380 to 480 46.8 84

Specifications

Input (AC rms)

Model Single-phase output Single-phase/three-phase switchable model
    PCR1000WEA PCR2000WEA PCR3000WEA2 PCR6000WEA2 PCR12000WEA2 PCR18000WEA2 PCR24000WEA2 PCR30000WEA2 PCR36000WEA2
    PCR6000WEA2R PCR12000WEA2R PCR18000WEA2R PCR24000WEA2R PCR30000WEA2R PCR36000WEA2R
Nominal input voltage 1P2W input model 100 Vac to 120 Vac / 200 Vac to 240 Vac *1
3P3W 200 V input model / 3P3W 400 V input model 200 Vac to 240 Vac (3 phase line voltage) *2 / 380 Vac to 480 Vac (3 phase line voltage) *2 *6
3P4W input model 380 Vac to 480 Vac (3 phase line voltage) *3
Phase Single-phase Three-phase
Nominal input Frequency 50 Hz to 60 Hz
Input frequency range 45 Hz to 65 Hz
Apparent power 1.4 kVA and less 2.7 kVA and less 4 kVA and less 7.8 kVA and less 15.6 kVA and less 23.4 kVA and less 31.2 kVA and less 39 kVA and less 46.8 kVA and less
Power factor *4 0.95(TYP) 200 V: 0.97(TYP), 400 V: 0.95(TYP) 3P3W input model / 0.95(TYP) 3P4W input model
Maximum current 1P2W input model *1 17 A / 8.5 A 32 A / 16 A 48 A / 24 A
3P3W 200 V input model 27 A 53 A 80 A 106 A 133 A 159 A
3P3W 400 V input model   14 A 28 A 42 A 56 A 70 A 84 A
3P4W input model 14 A 28 A 42 A 56 A 70 A 84 A
Hold-up time for power interruption *4 10 ms
Protective conductor current *5 1P2W input model 3.5 mA or less
3P3W 200 V input model 10 mA or less 15 mA or less 20 mA or less 25 mA or less 30 mA or less 35 mA or less
3P3W 400 V input model 10 mA or less 20 mA or less 30 mA or less 40 mA or less 50 mA or less 60 mA or less
3P4W input model 3.5 mA or less

*1 100 V/200 V input system (auto select)
*2 Models with an “R” in the name (6 kVA or higher) have a three-phase, three-wire input.
*3 Models of 6 kVA or more without an “R” in the name have three-phase 4-wire input.
*4 At output voltage 100 V/200 V, rated output current, sine wave, load power factor 1, output frequency 40 Hz to 1 kHz
*5 At output voltage 100 V/200 V, rated output current, sine wave, load power factor 1, output frequency 45 Hz to 65 Hz
*6 For the 400V input model, do not connect to transformer equipment with isolation voltage exceed-ing 300 V. It cannot be connected to a delta-connected power distribution facility with one pole grounded.

Output

Model Single-phase output Single-phase/three-phase switchable model
    PCR1000WEA PCR2000WEA PCR3000WEA2 PCR6000WEA2 PCR12000WEA2 PCR18000WEA2 PCR24000WEA2 PCR30000WEA2 PCR36000WEA2
    PCR6000WEA2R PCR12000WEA2R PCR18000WEA2R PCR24000WEA2R PCR30000WEA2R PCR36000WEA2R
Maximum peak current
*11
4 times the maximum output current
Inrush current capacity *3 3 times the rated current (0.07 s)
*12


1.4 times the rated current (0.5 s)
1.4 times the rated current (0.5 s)
Efficiency
*10
82 %(TYP) 85 %(TYP)

AC voltage

AC voltage *1 Rating 160 V / 320 V *2
Setting range 0 V to 161.0 V, 0 V to 322.0 V
Resolution 0.1 V
Setting accuracy (phase voltage) *3 *4 ±(0.3 % of setting + 0.3 V), ±(0.3 % of setting + 0.6 V)
Setting accuracy (Line voltage) *3 *4 ±(0.3 % of setting + 0.3 V), ±(0.3 % of setting + 0.6 V) *5
Maximum current *1 *6 Single-phase output 10 A / 5 A 20 A / 10 A 30 A / 15 A 60 A / 30 A 120 A / 60 A 180 A / 90 A 240 A / 120 A 300 A / 150 A 360 A / 180 A
Single-phase three-wire output, Three-phase output 10 A / 5 A 20 A / 10 A 40 A / 20 A 60 A / 30 A 80 A / 40 A 100 A / 50 A 120 A / 60 A
Phase 1P 1P2W, 1P3W, 3P4W switchable
Power capacity Single-phase output 1 kVA 2 kVA 3 kVA 6 kVA 12 kVA 18 kVA 24 kVA 30 kVA 36 kVA
Three-phase output 3 kVA 6 kVA 12 kVA 18 kVA 24 kVA 30 kVA 36 kVA
Single-phase three-wire output 2 kVA 4 kVA 8 kVA 12 kVA 16 kVA 20 kVA 24 kVA
Load power factor 0 to 1 (leading or lagging)
Frequency Setting range 1 Hz to 5 kHz *7 (5 kHz -3dB, <40 Hz derating required)
Resolution 0.01 Hz(1.00 Hz to 100.0 Hz), 0.1 Hz(100.0 Hz to 1000 Hz), 1 Hz(1000 Hz to 5000 Hz)
Accuracy *3 ±0.01 %, Temperature coefficient : ±0.005 %/°C
Phase Resolution 0.01
*13
, 0.1° (1 Hz to 500 Hz), 1° (500 Hz to 4 kHz), 2° (4 kHz or more)
Accuracy *3 Within ±(0.4° + fo×0.9°) *8 fo: frequency [kHz] [kHz]

DC voltage

DC voltage Rating *1 -226 V to +226 V, -452 V to +452 V *2
Setting range *1 -227.5 V to +227.5 V, -455.0 V to +455.0 V
Resolution 0.1 V
Accuracy *9 ±(0.05 % of setting + 0.1 V)
Maximum current *6 10 A / 5 A 20 A / 10 A 30 A / 15 A 60 A / 30 A 120 A / 60 A 180 A / 90 A 240 A / 120 A 300 A / 150 A 360 A / 180 A
Power capacity 1 kW 2 kW 3 kW 6 kW 12 kW 18 kW 24 kW 30 kW 36 kW

*1 output L range, output H range
*2 Specification guaranteed voltage range is 1 V to 160 V/ 2 V to 320 V (AC) and 1.4 V to 226 V/ 2.8 V to 452 V (DC)
*3 At ambient temperature of 23 °C±5 °C.
*4 No load, output frequency 45 Hz to 65 Hz
*5 When the phase angle of 120° of each phase.
*6 For output phase voltage of 100 Vac to 160 Vac/ 200 Vac to 320 Vac and out-put voltage of 100 Vdc to 226 Vdc/ 200 Vdc to 452 Vdc, output current is reduced with output voltage.
When the output frequency is between 1 Hz and 40 Hz, the output current is reduced by the output frequency. The output current is 70 % at 1 Hz.
*7 On the 500 Hz limit model, the frequency is limited to 1 Hz to 500.0 Hz for three-phase output.
*8 Within ±(0.4° + 2.5 μs×360°×fo×103). The following show the angles obtained by calculating the expression with the specified frequency, within ± 0.5° (at 60 Hz output), within ± 0.8° (at 400 Hz output)
*9 With no load at 23°C±5°C.
*10 When the output voltage is 100 V or 200 V, the output current is the rated value, the load power factor is 1, and the output frequency is between 40 Hz and 1 kHz.
*11 Repeated output is possible when the crest factor is 4.
*12 125 Vac/ 250 Vac (output L range/ H range)
*13 Waveform bank 0, at 1 Hz to 500 Hz.

Output Voltage Stability (Phase Voltage)

Model Single-phase output Single-phase/three-phase switchable model
  PCR1000WEA PCR2000WEA PCR3000WEA2 PCR6000WEA2 PCR12000WEA2 PCR18000WEA2 PCR24000WEA2 PCR30000WEA2 PCR36000WEA2
  PCR6000WEA2R PCR12000WEA2R PCR18000WEA2R PCR24000WEA2R PCR30000WEA2R PCR36000WEA2R
Line regulation *1 Within ±0.1 %
Load regulation *2 Within ±0.1 V/ ±0.2 V(1 Hz to 100 Hz)
Within ±0.3 V/ ±0.6 V(100.1 Hz to 500 Hz)
Within ±1 V/ ±2 V(500.1 Hz to 1 kHz)
Within ±0.2 V/ ±0.4 V(1 Hz to 100 Hz)
Within ±0.3 V/ ±0.6 V(100.1 Hz to 500 Hz)
Within ±1 V/ ±2 V(500.1 Hz to 1 kHz)
Output frequency variation *3 When the output voltage correction function is enabled : Within ±0.3 %(1 Hz to 1 kHz), Within ±10 %(1001 Hz to 5 kHz) When the output voltage correction function is disabled : Within -3 dB(5 kHz)
Ripple noise *4 ≤ 0.25 Vrms
Ambient temperature variation *5 ±100 ppm/ °C (TYP)
Total harmonic distortion *6 0.3 % and less(1 Hz to 100 Hz), 0.5 % and less(100.1 Hz to 330 Hz), 1.5 %/kHz and less(330.1 Hz to 5 kHz)
Transient response *7 Response FAST : 40 μs(TYP)
Response speed Tr/Tf *8 Response FAST : 40 μs(TYP) Response MEDIUM : 100 μs(TYP) Response SLOW : 300 μs(TYP)

*1 With respect to changes in the rated range of input voltage.
*2 With respect to 0 % to 100 % changes in the rating of output current. When the output phase voltage is between 80 V and 160 V (L range) or 160 V and 320 V (H range) and the load power factor is 1, and the response is FAST. At the output terminal block, when the compensation function is not used.
*3 Voltage variation over 40 Hz to 5 kHz in AC mode with 55 Hz as the reference. When the output phase voltage is between 80 V and 160 V or 160 V and 320 V and the load power factor is 1, and the response is FAST, at the output terminal block.
*4 5 Hz to 1 MHz components in DC mode.
*5 With respect to changes in the operating temperature range. When the output phase voltage is 100 V or 200 V, with no load.
*6 When the output phase voltage is between 80 V and 160 V or 160 V and 320 V and the load power factor is 1, and the response is FAST, at the output terminal block.
*7 When the output voltage is 100 V or 200 V, the load power factor is 1, and the output current changes from 0 A to the rated value and from the rated value to 0 A.
*8 At 10 % to 90 % of the output voltage.

Measurement

Model Single-phase output Single-phase/three-phase switchable model
    PCR1000WEA PCR2000WEA PCR3000WEA2 PCR6000WEA2 PCR12000WEA2 PCR18000WEA2 PCR24000WEA2 PCR30000WEA2 PCR36000WEA2
    PCR6000WEA2R PCR12000WEA2R PCR18000WEA2R PCR24000WEA2R PCR30000WEA2R PCR36000WEA2R
Voltage Rms value Resolution 0.1 V
Accuracy *1 DC, 40 Hz to 999.9 Hz : ±(0.3 % of reading +1 V), 1 kHz to 5 kHz : ±(0.5 % of reading +1 V)
Current Rms value Resolution 0 to 99.99 A: 0.01 A, 100 to 999.9 A: 0.1 A
Accuracy *1 *2 45 Hz to 65 Hz : ±(0.3 % of reading +0.3 % of f.s) DC, 40 Hz to 999.9 Hz : ±(0.6 % of reading +0.6 % of f.s)
1 kHz to 5 kHz : ±(1.2 % of reading +1.2 % of f.s)
Current peak value Resolution 0 to 99.99 A: 0.01 A, 100 to 999.9 A: 0.1 A
Accuracy *1 *3 4 % of f.s
Active power Resolution 1 W *5
Accuracy *1 *2 *4 45 Hz to 65 Hz : ±(0.3 % of reading +0.3 % of f.s)
Apparent power Resolution 1 VA *6
Apparent power Resolution 0.01
Power factor Resolution 0.1°
Harmonic measurement Frequency range
(fundamental wave)
10 Hz to 1 kHz
Upper limit of harmonic analysis 5th to 50th
FFT data length 4096
Measurement items Rms voltage and current, phase angle, THD
Recommended calibration period 1 year

*1 At ambient temperature of 23 °C±5 °C.
*2 At 10 % to 100 % of maximum rated current, sine wave.
*3 Pulse height of sine wave
*4 At a power factor of 1.
*5 When the measured value is 0 to less than 100 W, the resolution is 0.1 W.
*6 When the measured value is 0 to less than 100 VA, the resolution is 0.1 VA.

General

Model Single-phase output Single-phase/three-phase switchable model
    PCR1000WEA PCR2000WEA PCR3000WEA2 PCR6000WEA2 PCR12000WEA2 PCR18000WEA2 PCR24000WEA2 PCR30000WEA2 PCR36000WEA2
    PCR6000WEA2R PCR12000WEA2R PCR18000WEA2R PCR24000WEA2R PCR30000WEA2R PCR36000WEA2R
Insulation resistance Between input and chassis, output and chassis, and input and output 500 Vdc, 10 MΩ or more
Withstanding voltage Between input and chassis, output and chassis, and input and output 1500 Vac / 2150 Vdc, 1 minute
Electromagnetic compatibility *1 *2 Complies with the requirements of the following directive and standards.
EMC Directive 2014/30/EU EN 61326-1 (Class A*3), EN 55011 (Class A*3, Group 1*4), EN 61000-3-2*5, EN 61000-3-3*5
Applicable under the following conditions The maximum length of all cabling and wiring connected to the product must be less than 3 m.
Complies with the requirements of the following directive and standards.
EMC Directive 2014/30/EU EN 61326-1 (Class A*3) EN 55011 (Class A*3, Group 1*4)
Applicable under the following conditions The maximum length of all cabling and wiring connected to the product must be less than 3 m.
Safety Complies with the requirements of the following directive and standards.
Low Voltage Directive 2014/35/EU*2, EN 61010-1 (Class I*6, Pollution Degree 2*7), UL 61010-1*8, CAN / CSA -C 22.2 NO.61010-1*8
Environmental conditions Operating environment Indoor use, overvoltage category II
Operating temperature range 0 °C to +50 °C (32 °F to +122 °F)
Storage temperature range -10 °C to +60 °C (14 °F to +140 °F)
Operating humidity range 20 %rh to 80 %rh (no condensation)
Storage humidity range 90 %rh and less (no condensation)
Altitude Up to 2000 m
Weight Models without regeneration function 18 kg(39.68 Ib)
21 kg *8(46.3 lb)
21 kg (46.3 lb)
24 kg *8(52.9 lb)
Approx. 25 kg(55.12 Ib)
28 kg *8(61.7 lb)
43 kg (94.8 lb) 66 kg (145.5 lb) 120 kg (264.6 lb) Approx. 130 kg (286.60 lbs) Approx. 160 kg (352.74 lbs) 180 kg (396.8 lb)
200 V input models with regeneration function 43 kg (94.8 lb) 67 kg (147.7 lb) 120 kg (264.6 lb) Approx. 130 kg (286.60 lbs) Approx. 160 kg (352.74 lbs) 180 kg (396.8 lb)
400 V input models with regeneration function 46 kg (101.4 lb) 70 kg (154.3 lb) 120 kg (264.6 lb) 140 kg (308.6 lb) 170 kg (374.8 lb) 180 kg (396.8 lb)
Input terminal M6 M5 3P3W input model: M8,
3P4W input model: M5
Output terminal M6 M5 M6 M8
Accessories Cable tie (4 pcs.), External control(DIGITAL I/O) connector (1 pc.), Heavy object warning label (1 pc.)*Excludes PCR1000WEA, Read This First! (1 copy), Quick Reference(1 sheet), CD-ROM (1 disc), Safety Information (1 copy)

*1 Does not apply to specially ordered or modified products.
*2 Only on models that have the CE marking on the panel.
*3 This is Class A equipment. This product is intended for use in an industrial environment. This product may cause interference if used in residential areas. Such use must be avoided unless the user takes special measures to reduce electromagnetic emissions to prevent interference to the reception of radio and television broadcasts.
*4 This is Group 1 equipment. This product does not generate and/or use intentionally radio-frequency energy, in the form of electromagnetic radiation, inductive and/or capacitive coupling, for the treatment of material or inspection/analysis purpose.
*5 This does not apply to the PCR6000WEA2R (3-phase 3-wire 200V input model).
*6 This is Class I equipment. Be sure to ground this product’s protective conductor terminal. The safety of this product is only guaranteed when the product is properly grounded.
*7 Pollution is addition of foreign matter (solid, liquid or gaseous) that may produce a reduction of dielectric strength or surface resistivity. Pollution Degree 2 assumes that only nonconductive pollution will occur except for an occasional temporary conductivity caused by condensation.
*8 Only on models that have cTUVus marking on the panel.

Output Impedance Setting

Model Single-phase output Single-phase/three-phase switchable model
    PCR1000WEA PCR2000WEA PCR3000WEA2 PCR6000WEA2 PCR12000WEA2 PCR18000WEA2 PCR24000WEA2 PCR30000WEA2 PCR36000WEA2
    PCR6000WEA2R PCR12000WEA2R PCR18000WEA2R PCR24000WEA2R PCR30000WEA2R PCR36000WEA2R
L range 1P 0 Ω to 2000 mΩ 0 Ω to 1000 m Ω 0 Ω to 667 mΩ 0 Ω to 333 mΩ 0 Ω to 167 m Ω 0 Ω to 111 m Ω 0 Ω to 83 m Ω 0 Ω to 67 m Ω 0 Ω to 56 m Ω
1P3W
3P
0 Ω to 2000 mΩ 0 Ω to 1000 m Ω 0 Ω to 500 m Ω 0 Ω to 333 m Ω 0 Ω to 250 m Ω 0 Ω to 200 m Ω 0 Ω to 167 m Ω
H range 1P 0 Ω to 8000 m Ω 0 Ω to 4000 m Ω 0 Ω to 2667 m Ω 0 Ω to 1333 m Ω 0 Ω to 667 m Ω 0 Ω to 444 m Ω 0 Ω to 333 m Ω 0 Ω to 267 m Ω 0 Ω to 222 m Ω
1P3W
3P
0 Ω to 8000 m Ω 0 Ω to 4000 m Ω 0 Ω to 2000 mΩ 0 Ω to 1333 m Ω 0 Ω to 1000 m Ω 0 Ω to 800 m Ω 0 Ω to 667 m Ω

Output Impedance Setting – Reactance component [Response: FAST]

Model Single-phase output Single-phase/three-phase switchable model
    PCR1000WEA PCR2000WEA PCR3000WEA2 PCR6000WEA2 PCR12000WEA2 PCR18000WEA2 PCR24000WEA2 PCR30000WEA2 PCR36000WEA2
    PCR6000WEA2R PCR12000WEA2R PCR18000WEA2R PCR24000WEA2R PCR30000WEA2R PCR36000WEA2R
L range 1P 40 μH to 2000 μH 20 μH to 1000 μH 13 μH to 667 μH 7 μH to 333 μH 3 μH to 167 μH 2 μH to 111 μH 2 μH to 83 μH 1 μH to 67 μH 1 μH to 56 μH
1P3W
3P
40 μH to 2000 μH 20 μH to 1000 μH 10 μH to 500 μH 7 μH to 333 μH 5 μH to 250 μH 4 μH to 200 μH 3 μH to 167 μH
H range 1P 160 μH to 8000 μH 80 μH to 4000 μH 53 μH to 2667 μH 27 μH to 1333 μH 13 μH to 667 μH 9 μH to 444 μH 7 μH to 333 μH 5 μH to 267 μH 4 μH to 222 μH
1P3W
3P
160 μH to 8000 μH 80 μH to 4000 μH 40 μH to 2000 μH 27 μH to 1333 μH 20 μH to 1000 μH 16 μH to 800 μH 13 μH to 667 μH

Output Impedance Setting – Reactance component [Response: MED]

Model Single-phase output Single-phase/three-phase switchable model
    PCR1000WEA PCR2000WEA PCR3000WEA2 PCR6000WEA2 PCR12000WEA2 PCR18000WEA2 PCR24000WEA2 PCR30000WEA2 PCR36000WEA2
    PCR6000WEA2R PCR12000WEA2R PCR18000WEA2R PCR24000WEA2R PCR30000WEA2R PCR36000WEA2R
L range 1P 80 μH to 2000 μH 40 μH to 1000 μH 27 μH to 667 μH 13 μH to 333 μH 7 μH to 167 μH 4 μH to 111 μH 3 μH to 83 μH 3 μH to 67 μH 2 μH to 56 μH
1P3W
3P
80 μH to 2000 μH 40 μH to 1000 μH 20 μH to 500 μH 13 μH to 333 μH 10 μH to 250 μH 8 μH to 200 μH 7 μH to 167 μH
H range 1P 320 μH to 8000 μH 160 μH to 4000 μH 107 μH to 2667 μH 53 μH to 1333 μH 27 μH to 667 μH 18 μH to 444 μH 13 μH to 333 μH 11 μH to 267 μH 9 μH to 222 μH
1P3W
3P
320 μH to 8000 μH 160 μH to 4000 μH 80 μH to 2000 μH 53 μH to 1333 μH 40 μH to 1000 μH 32 μH to 800 μH 27 μH to 667 μH

Output Impedance Setting – Reactance component [Response: SLOW]

Model Single-phase output Single-phase/three-phase switchable model
    PCR1000WEA PCR2000WEA PCR3000WEA2 PCR6000WEA2 PCR12000WEA2 PCR18000WEA2 PCR24000WEA2 PCR30000WEA2 PCR36000WEA2
    PCR6000WEA2R PCR12000WEA2R PCR18000WEA2R PCR24000WEA2R PCR30000WEA2R PCR36000WEA2R
L range 1P 240 μH to 2000 μH 120 μH to 1000 μH 80 μH to 667 μH 40 μH to 333 μH 20 μH to 167 μH 13 μH to 111 μH 10 μH to 83 μH 8 μH to 67 μH 7 μH to 56 μH
1P3W
3P
240 μH to 2000 μH 120 μH to 1000 μH 60 μH to 500 μH 40 μH to 333 μH 30 μH to 250 μH 24 μH to 200 μH 20 μH to 167 μH
H range 1P 960 μH to 8000 μH 480 μH to 4000 μH 320 μH to 2667 μH 160 μH to 1333 μH 80 μH to 667 μH 53 μH to 444 μH 40 μH to 333 μH 32 μH to 267 μH 27 μH to 222 μH
1P3W
3P
960 μH to 8000 μH 480 μH to 4000 μH 240 μH to 2000 μH 160 μH to 1333 μH 120 μH to 1000 μH 96 μH to 800 μH 80 μH to 667 μH

Limit Values and Protection Functions (Common Specification)

  Setting range Resolution
Voltage protection AC voltage upper limit
AC voltage lower limit
0.0 V to 322.0 V 0.1 V
DC voltage upper limit
DC voltage lower limit
-455 V to 455 V 0.1 V
Output overvoltage protection(OVP) Rms value 14.0 V to 500.5 V 0.1 V
Positive peak value
Negative peak value
14.0 V to 500.5 V
-500.5 V to -14.0 V
0.1 V
Power module overvoltage protection Fixed
Output undervoltage protection (UVP) 0.0 V to 500.5 V 0.1 V
Frequency protection Frequency upper limit
Frequency lower limit
1 Hz to 5000 Hz
500 Hz LMT model: 1 Hz to 500 Hz
(Three-phase output)
0.01 Hz (1.00 Hz to 100.0 Hz), 0.1 Hz (100.0 Hz to 1000 Hz), 1 Hz (1000 Hz to 5000 Hz)
Current protection Current limit *1 Maximum output current × 0.1
to maximum output current × 1.1
0.01 A (0.35 A to 100.0 A), 0.1 A (100.0 A to 1000 A)
Positive peak current limit
Negative peak current limit *2
Maximum output current × 0.1
to maximum output current × 4.2
Overheat protection Power module overheat protection Fixed
Fan error Fixed
Overload protection Rated current or current limit Current limit resolution
Independent operation detection Fixed
Sensing error detection ±(10 % +10 V) with respect to the output terminal voltage

*1 The current that can actually be supplied is 1.1 times the rated current or the current limit, whichever is less.
*2 The current that can actually be supplied is the maximum peak current or the current limit, whichever is less.

Communication Interface (Common Specification)

USB Complies with the USB 2.0 specifications; data rate: 480 Mbps (high speed), socket B type, self-powered,
Complies with the USBTMC-USB488 device class specifications.
LAN IEEE802.3, 100Base-TX Ethernet LXI Rev.1.5 2016 (extended functions: VXI-11, HiSLIP, IPv6), data rate: 100 Mbps (auto negotiation, full speed)
AUTO MDIX function IPv4, RJ45 connector, category 5, straight cable Complies with SCPI Specification 1999.0
RS232C Complies with the EIA232D specifications, asynchronous full duplex, D-SUB 9-pin connector (male), crossover cable (null modem),
9600bps/19200bps/38400bps/57600bps/115200bps
GPIB(option) Complies with IEEE Std 488.1-1987
SH1, AH1, T8, L4, SR0, RL0, PP0, DC0, DT0, C0, E1 24-pin connector (receptacle)